|
Revvity
cellometer auto t4 bright field cell counter Cellometer Auto T4 Bright Field Cell Counter, supplied by Revvity, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/cellometer auto t4 bright field cell counter/product/Revvity Average 98 stars, based on 1 article reviews
cellometer auto t4 bright field cell counter - by Bioz Stars,
2026-03
98/100 stars
|
Buy from Supplier |
|
Bio-Rad
tc20 automated cell counter Tc20 Automated Cell Counter, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/tc20 automated cell counter/product/Bio-Rad Average 97 stars, based on 1 article reviews
tc20 automated cell counter - by Bioz Stars,
2026-03
97/100 stars
|
Buy from Supplier |
|
Revvity
celigo image cytometer Celigo Image Cytometer, supplied by Revvity, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/celigo image cytometer/product/Revvity Average 99 stars, based on 1 article reviews
celigo image cytometer - by Bioz Stars,
2026-03
99/100 stars
|
Buy from Supplier |
|
Bio-Rad
cell counting slides Cell Counting Slides, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/cell counting slides/product/Bio-Rad Average 96 stars, based on 1 article reviews
cell counting slides - by Bioz Stars,
2026-03
96/100 stars
|
Buy from Supplier |
|
Revvity
perkin elmer spectrum Perkin Elmer Spectrum, supplied by Revvity, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/perkin elmer spectrum/product/Revvity Average 98 stars, based on 1 article reviews
perkin elmer spectrum - by Bioz Stars,
2026-03
98/100 stars
|
Buy from Supplier |
|
Revvity
opera phenix high content screening system Opera Phenix High Content Screening System, supplied by Revvity, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/opera phenix high content screening system/product/Revvity Average 99 stars, based on 1 article reviews
opera phenix high content screening system - by Bioz Stars,
2026-03
99/100 stars
|
Buy from Supplier |
|
Revvity
cellometer vision cell counter ![]() Cellometer Vision Cell Counter, supplied by Revvity, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/cellometer vision cell counter/product/Revvity Average 98 stars, based on 1 article reviews
cellometer vision cell counter - by Bioz Stars,
2026-03
98/100 stars
|
Buy from Supplier |
|
Revvity
cellometer k2 fluorescent viability cell counter ![]() Cellometer K2 Fluorescent Viability Cell Counter, supplied by Revvity, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/cellometer k2 fluorescent viability cell counter/product/Revvity Average 98 stars, based on 1 article reviews
cellometer k2 fluorescent viability cell counter - by Bioz Stars,
2026-03
98/100 stars
|
Buy from Supplier |
|
Revvity
cellacamx ![]() Cellacamx, supplied by Revvity, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/cellacamx/product/Revvity Average 96 stars, based on 1 article reviews
cellacamx - by Bioz Stars,
2026-03
96/100 stars
|
Buy from Supplier |
|
Evident Corporation
cell counter model r1 ![]() Cell Counter Model R1, supplied by Evident Corporation, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/cell counter model r1/product/Evident Corporation Average 95 stars, based on 1 article reviews
cell counter model r1 - by Bioz Stars,
2026-03
95/100 stars
|
Buy from Supplier |
|
Revvity
ivis lumina system ![]() Ivis Lumina System, supplied by Revvity, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/ivis lumina system/product/Revvity Average 99 stars, based on 1 article reviews
ivis lumina system - by Bioz Stars,
2026-03
99/100 stars
|
Buy from Supplier |
|
Revvity
envision reader ![]() Envision Reader, supplied by Revvity, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/envision reader/product/Revvity Average 99 stars, based on 1 article reviews
envision reader - by Bioz Stars,
2026-03
99/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Toxicological Sciences
Article Title: MDR1 Transporter Protects Against Paraquat-Induced Toxicity in Human and Mouse Proximal Tubule Cells
doi: 10.1093/toxsci/kfu141
Figure Lengend Snippet: Paraquat accumulation in MDR1-transfected HEK293 cells. HEK293 cells were stably transfected with empty vector (EV) or full-length human MDR1 plasmids. (A) Protein expression of MDR1 was detected by Western blot analysis. β-actin was used as a loading control. HEK-EV and MDR1 transfected cells were treated with rhodamine 123 (25 μM) or paraquat (100 μM) for 30 min (uptake period), washed, and then incubated in fresh culture medium for 60 min (efflux period). (B) Intracellular fluorescence of rhodamine 123 was detected using a Nexcelom Cellometer Vision and expressed as relative fluorescence units. (C) Intracellular paraquat accumulation was quantified by ELISA and normalized to protein lysate concentrations. Data are presented as mean ± SE (n = 4). Asterisks (*) represent statistically significant differences (p < 0.05) compared with HEK-EV cells.
Article Snippet: Following washing and centrifugation, the cell pellet was suspended in PBS and the intensity of fluorescence for each cell was quantified on a
Techniques: Transfection, Stable Transfection, Plasmid Preparation, Expressing, Western Blot, Control, Incubation, Fluorescence, Enzyme-linked Immunosorbent Assay
Journal: Toxicological Sciences
Article Title: MDR1 Transporter Protects Against Paraquat-Induced Toxicity in Human and Mouse Proximal Tubule Cells
doi: 10.1093/toxsci/kfu141
Figure Lengend Snippet: Expression and function of MDR1 transporter in RPTEC cells. (A) Protein expression of MDR1 in RPTEC cells was detected by Western blot analysis. (B) RPTEC cells were treated with rhodamine 123 (25 μM) in the presence or absence of the MDR1 inhibitor, PSC833 (2 μM), for 30 min (uptake period) and then treated with the culture media with or without PSC833 (2 μM) for 60 min (efflux period). Intracellular fluorescence of rhodamine 123 was detected using a Nexcelom Cellometer Vision and expressed as relative fluorescence units. Data are presented as mean ± SE (n = 4). Asterisk (*) represents statistically significant differences (p < 0.05) compared with RPTEC cells treated only with rhodamine 123 (no PSC833).
Article Snippet: Following washing and centrifugation, the cell pellet was suspended in PBS and the intensity of fluorescence for each cell was quantified on a
Techniques: Expressing, Western Blot, Fluorescence
Journal: Toxicological Sciences
Article Title: MDR1 Transporter Protects Against Paraquat-Induced Toxicity in Human and Mouse Proximal Tubule Cells
doi: 10.1093/toxsci/kfu141
Figure Lengend Snippet: Paraquat accumulation in RPTEC cells following siRNA knockdown of MDR1. RPTEC cells were transfected with siRNA duplexes targeted against human MDR1. (A) Protein expression of MDR1 at 72 h was assessed by Western blot analysis. (B) RPTEC cells were treated with rhodamine 123 (25 μM) in the presence or absence of the MDR1 inhibitor, PSC833 (2 μM), for 30 min (uptake period), washed, and then incubated in fresh culture media with or without PSC833 (2 μM) for 60 min (efflux period). MDR1 siRNA transfected RPTEC cells were treated with rhodamine (25 μM) for 30 min (uptake period), washed, and then incubated in fresh culture media for 60 min (efflux period). Intracellular fluorescence of rhodamine 123 was detected using a Nexcelom Cellometer Vision and expressed as relative fluorescence units. (C) RPTEC cells were treated as described in (B) using paraquat (100 μM) as a substrate. Intracellular paraquat accumulation was quantified by ELISA and normalized to protein concentrations of the cellular lysates. Data are presented as mean ± SE (n = 4). Asterisks (*) represent statistically significant differences (p < 0.05) compared with RPTEC cells without PSC833 or MDR1 siRNA.
Article Snippet: Following washing and centrifugation, the cell pellet was suspended in PBS and the intensity of fluorescence for each cell was quantified on a
Techniques: Knockdown, Transfection, Expressing, Western Blot, Incubation, Fluorescence, Enzyme-linked Immunosorbent Assay